Hanging combine harvester use points

(1) Do the maintenance work before entering the field. For example, it is necessary to add lubricant to the various transmission and rotating parts of the tractor and combine according to the instructions. In particular, add oil to the PTO reel assembly and clean the dust and grass on the engine radiator before daily harvesting. Crumbs. (2) Before the harvest, it is necessary to do a good job of the "big three" adjustment of the harvester. One is to adjust the cutter. Put the movable arbor to the limit position, adjust the center line of the power sheet to coincide with the centerline of the razor guard (the deviation is not more than 5mm), and then the center line pairs of the movable and stationary blades coincide, and The clearance is adjusted to 0.1-0.5 mm, the gap between the two blades is adjusted to 0.5-1.5 mm, and the gap between the press blade and the moving blade is adjusted to 0.1-0.8 mm. The second is to adjust the pull wheel. Turn the pull-out wheel to the lowest position, adjust the iron teeth on the web to be perpendicular to the ground, and adjust it to act on the top 1/3 of the crop, and then adjust the front and rear position of the pull-out wheel to “pull. The harmonious location of the cocoon and the store." The third is to adjust agitation. The gap between the agitator blade and the bottom plate of the header is adjusted to 10 to 18 mm, and the tension of the conveyor belt in the conveyor tank is adjusted to the bottom of the groove when the belt is moved. When the header is raised to the highest, the teeth do not touch the auger. blade. (3) Some harvesters just entered the field cutting, not long to cut the table, stir the dragon, and the drum was blocked. This is an annoying thing that many new combine harvesters will encounter. In fact, this is only because the low-speed throttle is used when starting the cut. As long as the low gear is selected before starting the cut, the high output of the power output shaft is selected, and the throttle is cut with the medium and large throttles, generally no jamming will occur. However, when the dew is heavy and the crop is dense, it is necessary to use half-cutting or high stubble to prevent clogging. In addition, when the machine enters the field, it is necessary to cut about 15 meters along the right from the corner of the field, and then reverse the second and third sections to make the turning of the machinery. At this time, to observe the cleanliness of the grain and the loss of the shell opening, adjust the air volume adjustment plate to an appropriate position.

KDLED700+500 (3)

LED-Q5


Germany imported beads

Imported French lens

mould Die-casting  Eight edge type Revolving arm

Optional emergency power supply≥3 hours



led (1)

Led operating light



1)Ideal cold light effects

Using the new LED cold light source, ensure energy saving and environmental protection and long service life up to 80,000hours and more.

The temperature increase of surgeon`s head below 1℃. LED do not engender infrared ray and ultraviolet radiation, without the temperature

rise and tissue damage caused by halogen shadowless light, also it can accelerate the wound healing after surgery, and without Radiation pollution.

With color temperature constant and soft, LED is very close to the sunshine.

1) Excellent shadowless effect

Lamp with the most scientific radian and Multi point light source design, ensure better uniform illuminance. When the lamps are partially occluded,

also can achieve perfect shadowless effect.Lamp panel radius of gyration ≥182cm, the lamp can be pulled to vertical floor, convenient to any angle illumination.

2) Excellent deep lighting

It is based on modularize method by Computer Aided Design, focused to irradiating with more beams of LED. It produces the deep lighting which beams

more than 1200cm,the illumination of center up to 180,000Lux or more, and offer the color temperature that can be adjusted from 3700K to 5000K which

is close to sunshine. Absolutely, it really reflects the color of human tissue and satisfied by all kinds of operating light needs.

3) Advanced control system

The use of liquid crystal display button control, to meet the needs of the medical staff of different patients with the brightness of the operation.

It offers illuminance memory function.

It does not effect using when a single circuit or one bulb is broken.

4) Universal suspension system

Rotating arm, a new type of alloy material is made of eight edge type.

Balanced system using imported arm module, more than 5 group universal joints, every cantilever must has more than 3 joints which can be rotated in 360°,

The structure is light, easy to manipulate, accurate positioning, can provide the maximum range of regulation.The equipped with fatigue correcting unit and

fix position hand handle device, easy to fix position after long time use.

5) Modern laminar lamp

The thickest part of lamp-chimney is not more than 10cm.

The lamp-chimney is made of ABS, The handle on the central of lamp can be detachable, can take high temperature (≤ 134°C) sterilization treatment,

easily adjust, flexible fixed.



Double Dome Operating Light

Double Dome LED Operating Light,Double Dome Surgery Operating Lights,Operation Theatre Lights,Surgical Examination Light

Shandong Kang'erjian Medical Technology Ltd. , https://www.operatingtable.nl