Instructions for use of drying equipment

1. The box is placed on the dry floor and work surface in the room. The carbon dioxide incubator does not need to use other fixing devices.

2. A knives or air switch should be installed in the power supply line for the purpose of this box, and use a wire that is twice as thick as the cross-sectional area of ​​the power line as the grounding line.

3. Before powering on, check the electrical performance of the box first, and pay attention to whether there is open circuit or leakage.

4. When everything is ready, put in the test sample, close the door, and open the exhaust valve if necessary. The gap is about 10mm.

5, water-proof incubator, constant temperature water bath to connect distilled water or deionized water to the water inlet, add water to the overflow.

Use after power on:

6. After connecting the power supply, you can turn on the heating switch, and the drying box will set the temperature setting dial to the desired working temperature value. The water bath oscillator constant temperature incubator and the water-blocking incubator place the temperature “set-measure” switch to “set”. After adjusting the temperature setting knob to the required operating temperature, place the “set-measure” switch “Measurement”, at this time, the temperature inside the box starts to rise, and the green light is on (smart or special requirements, attached to the manual).

7. When the temperature rises to the required working temperature, turn to the green light to turn off, and then fine-tune to the green light to re-light. At this point, the indicator light is alternately turned off, which is the constant temperature point. At this time, the knob can be fine-tuned to the green light to be extinguished. Keep it constant (it is likely that the temperature will continue to rise at constant temperature, which is the effect of residual heat, which will be stable in about half an hour). When the temperature in the working chamber is stable (the so-called "constant temperature state"), the temperature controller can be slightly adjusted to improve the accuracy of the temperature control. Any operating temperature can be selected by this method.

8. When the drying box is at constant temperature, the electric heating constant temperature blast drying box should be turned off the high temperature switch, leaving only one set of electric heaters to work, so as to avoid excessive power and affect the constant temperature precision. When the working temperature is less than 150 °C, only one set of heaters is needed. The high temperature switch should be turned off.

9. After the temperature is reached, it can be kept constant for a certain period of time according to the test requirements (W type can set the constant temperature working time). In this process, the super constant temperature water bath can be automatically controlled by the temperature controller without adding manual management.