How to maintain the dehumidifier to make life last longer

Dehumidifier maintenance work should be paid attention to. When using the dehumidifier in the factory, there should be special personnel. When using the dehumidifier, the family should check whether the performance of all aspects of the dehumidifier is intact before the season. Please pay attention to the maintenance work of the dehumidifier, remember that the maintenance of the dehumidifier will save you a lot of maintenance costs.

First, the dehumidifier maintenance switch secret method

Industrial dehumidifiers should not be used frequently. Do not start and shut down the dehumidifier frequently because the room humidity has reached the required value or higher than the required value. Instead, let the dehumidifier control the start and stop by the humidity controller. When the dehumidifier is not in use, turn off the power and unplug the power cord. If the dehumidifier is shut down for any reason (such as sudden power failure, man-made shutdown, etc.), since the general dehumidifier has no time delay for stopping the machine (the delay time is about 3 minutes), the household dehumidifier can be turned on immediately after the machine is stopped. , but it takes 3 minutes to run.

However, for a dehumidifier without a time delay device, it cannot be turned on immediately after shutdown. It is necessary to restart the dehumidifier after about 3 minutes, otherwise the startup current may be too large, the fuse may be burned, or even the compressor motor may be burnt. Pay particular attention to the effective use of timing functions. When sleeping with the eyes and going out, use the timing function to operate only for the necessary time to save power.

Second, dehumidifier maintenance humidity secret method

Industrial dehumidifier operation should pay attention to carefully adjust the humidity to avoid too high or too low. If it is 2% lower, it can save about 10%. When the dehumidifier is running, open the doors and windows as little as possible. Frequent opening and closing of doors and windows will reduce the dehumidification effect of the dehumidifier and waste electricity. Especially in the summer, the direct sunlight blocking the dehumidifier can save about 5%. In addition, the space with good sealing conditions is the most energy efficient.

Third, dehumidifier maintenance filter network secret method

Among all household appliances, dehumidifiers and air conditioners are the most serious dust pollution, and dehumidifier cleaning is the most overlooked thing. Some users use the dehumidifier for many years and never use it until it fails. A considerable number of dehumidifiers for repair are prematurely damaged due to lack of cleaning and maintenance. Therefore, dehumidifiers are usually cleaned and maintained before the rainy season or after the fall. Especially the maintenance of the filter. After removing the air filter, gently pat or use a vacuum cleaner for cleaning. If the filter has too much dirt, it can be washed with water or a neutral detergent, but it should not be washed with hot water above 50 °C to avoid deformation. Do not use a sponge to clean, otherwise it will damage the surface of the filter. After washing with clean water, let it dry in a cool place. Do not expose it to sunlight or dry it by the stove, as it may cause deformation. After the air filter after air drying is installed back into the dehumidifier, the maintenance process of the entire dehumidifier is completed.

Fourth, dehumidifier maintenance components secret law

In the operation of the daily dehumidifier, care should be taken to protect the heat sink of the condenser and evaporator. The heat sink of the condenser and the evaporator is made of 0.112 mm aluminum sheet which is sleeved into the copper tube and can not withstand collision. If the heat sink is damaged, the heat dissipation effect of the dehumidifier will be affected, and the dehumidification efficiency will be reduced. In addition, the refrigeration system must be protected. If the components of the refrigeration system or the connecting lines are damaged, the refrigerant will leak and the dehumidifier will not be able to cool. Remove the movement every year and inject the appropriate lubricating oil into the fan motor bearings. The refrigeration system does not have to be treated, as long as the external dirt is removed. Also, the dehumidifier should use the fuse (fuse) correctly. According to the rated current indicated in the product manual, the specification of the fuse is selected. If it is too large, it will not be insured. If it is too small, it will often break.

Five, dehumidifier maintenance and taming Dafa

Do not cover the air outlet of the wet machine. When using the dry clothes function, the clothes should be separated from the air outlet of the dehumidifier as far as possible. When the articles are blocked by the air outlet of the dehumidifier, the wind circulation system is blocked, which will seriously damage the life of the household dehumidifier.