Calibration and error processing method of electronic forklift scale

Calibration steps for electronic forklift scales:

Step 1: The weight is greater than 1T, less than 2T (1.5T calibration)

Step 2: The forklift is raised about 2cm and calibrated
Step 3: Place the position in the middle of the table (the handle part)

Forklift scale weighing error processing method:

1. Raise the forklift to the highest position, insert a piece of paper into the gap between the scale and the fork cover to see if there is any place. If there is a problem, you can use the appropriate tool to tilt off.
2. Raise the fork cover, loosen the sensor retainer, use a large screwdriver to adjust it up, and then install the circlip. If the lower fork cover is removed, there is no adjustment screw on the sensor. You can loosen the circlip and then rotate the 4 screws in the cover 2-3 times.

3. Check if the circlip is touching the lever. If you touch it, you can directly remove the circlip and test the scale once. If the circlip is useful, it can be removed.